ANSUL

ANSUL Clean Agent Suppression

Clean agent suppression that puts the fire out without wetting or contaminating what it was protecting.

Explore Products
ANSUL Clean Agent
Brand overview

Clean Agent Suppression by ANSUL

ANSUL's clean agent systems suppress fire in an enclosure without leaving residue and without conducting electricity, so servers, switchgear and archives come through a discharge intact rather than being written off by the response.

Agent quantity is calculated to the protected volume and the design concentration, and a room integrity test at commissioning establishes that the enclosure will actually hold it. Intech designs, installs, commissions and maintains these systems.

  • No residue, no conductivity Equipment the fire never reached stays serviceable.
  • Sized to the volume Agent quantity follows a calculation, not a rule of thumb.
  • Integrity proven Room integrity testing at commissioning demonstrates the hold time.
  • Safe for occupants Discharge delay, clear warning and a manual lock-off.
System

How Clean Agent Suppression Works

01

Detect

Two independent detectors must confirm before anything is released.

02

Warn and hold

Occupants are alerted, with a discharge delay and a manual lock-off.

03

Discharge

The agent floods the enclosure and reaches design concentration in seconds.

04

Hold concentration

A sealed room keeps the agent long enough for the fire to be properly out.

Our services

ANSUL Clean Agent Supply, Installation and Support

Product selection and consultation

Choosing the right model for the application rather than the catalogue.

System design and engineering

Layout, sizing and the cause-and-effect where the system drives something.

Installation and commissioning

Installed, commissioned and proven as one tested sequence.

Upgrades and expansion

Extending or replacing an existing installation without starting again.

Preventive maintenance and AMC

Scheduled inspection and testing with a documented record.

Troubleshooting and support

Fault diagnosis from the team that commissioned the system.

Resources

ANSUL Clean Agent Datasheets

Every datasheet we hold for the range, linked directly. 1 documents.

Full range

The Complete ANSUL Clean Agent Range We Supply

Models & variants

FK5112/ NOVEC1230 BASED 25 & 70 BAR GAS SUPPRESSION SYSTEM

FK5112/ NOVEC1230 BASED 25 & 70 BAR GAS SUPPRESSION SYSTEM

Using water as a fire suppressant in areas where electronics operate and irreplaceable, high-value assets are stored, could be as devastating as fire itself. The SAPPHIRE Clean Agent System quickly suppresses fires and protects sensitive equipment without causing harm to people or the environment. The system is especially suited to suppress fires in areas where an electrically non-conductive medium is required, where electronic systems cannot be shut down in an emergency, where cleanup of other agents poses a problem, and in normally occupied areas that demand a non-toxic agent. Here we use FK5112/Novec1230 fire protection fluid for total flooding applications. The clear, colorless agent has zero ozone depletion potential, an atmospheric lifetime of just five days, and a global warming potential of 1.0. System suppresses a fire before it can be fully engaged and once the fire is suppress

Technical datasheet
FAQ

Frequently Asked Questions

What project teams usually ask about ANSUL Clean Agent.

Still have a question?

Speak directly with one of our fire safety engineers.

Call +91 88795 33000
What is ANSUL clean agent?
A clean agent extinguishing system. It suppresses fire without leaving residue, so the protected equipment comes through a discharge intact.
Is it safe for people in the room?
Systems are designed so the concentration suppresses fire while remaining survivable, with a discharge delay, clear warning and a manual lock-off.
Why does the room need sealing?
The agent must hold its concentration long enough for the fire to be out. An unsealed cable entry or oversized door gap leaks it away regardless of how much is installed.
What is a room integrity test?
A measured test at commissioning that establishes how long the enclosure holds the agent. It is how you know the system will work.
What happens after a discharge?
The room is ventilated and cylinders refilled. There is no residue to clean, so recovery is hours rather than weeks.
Does Intech design and maintain it?
Yes — volume calculation, room integrity testing, installation, commissioning and AMC including cylinder weighing.
Genuine product, direct OEM support

Protect Critical Rooms Without Water Damage

Tell us about the room and its contents and an engineer will size the system and quote supply and installation.