Addressable Fire Alarm Panel FC501
557.200.718 / FC501-H 557.200.719/ FC501-L 557.200.720 / FC501-HK
>
Skip to contentAddressable panels, detectors and monitoring software for code-compliant fire detection — supplied, installed and maintained by Intech.

Fireclass is an addressable fire detection range covering control panels, the FC460 detector series and the software that monitors them. Every device on the loop reports its own address, so the panel names the device in alarm rather than a zone covering a floor.
The range scales from a compact single-loop panel up to multi-panel installations monitored from one place, with detector types selected per area rather than applied uniformly. Intech supplies, commissions and maintains the range.
Which panel and detector mix suits your building comes out of the site assessment.

557.200.718 / FC501-H 557.200.719/ FC501-L 557.200.720 / FC501-HK

557.200.725 / FC503: 3 Loop Panel 250 Points 557.200.726 / FC506: 6 Loop Panel 500 Points 557.200.727 / FC500 FireClass Repeater

557.200.949 FC702S - One HP or two SP Loop FireClass Panel shallow housing 557.200.950 FC702D - One HP or two SP Loop FireClass Panel deep housing
Addressable detectors and call points report their own identity.
The panel resolves each address to a device and a location.
Sounders and visual alarm devices operate to the evacuation strategy.
Cause-and-effect drives suppression, lifts, dampers and door release.
Detection requirements differ considerably by building type; the panel platform may be the same but the devices on it are not.
Multi-tenant floors with phased evacuation.
Industry detailMixed areas with differing detection needs.
Industry detailGuest floors, kitchens and back-of-house.
Industry detailClean areas and solvent stores.
Industry detailProduction areas needing heat and multi-sensor devices.
Industry detailOccupancies with statutory detection requirements.
Industry detailChoosing the right model for the application rather than the catalogue.
Layout, sizing and the cause-and-effect where the system drives something.
Installed, commissioned and proven as one tested sequence.
Extending or replacing an existing installation without starting again.
Scheduled inspection and testing with a documented record.
Fault diagnosis from the team that commissioned the system.

557.200.718 / FC501-H 557.200.719/ FC501-L 557.200.720 / FC501-HK

557.200.725 / FC503: 3 Loop Panel 250 Points 557.200.726 / FC506: 6 Loop Panel 500 Points 557.200.727 / FC500 FireClass Repeater

557.200.949 FC702S - One HP or two SP Loop FireClass Panel shallow housing 557.200.950 FC702D - One HP or two SP Loop FireClass Panel deep housing

557.200.951 / FC708D - Two HP or four SP loop, expandable to eight loop, FireClass Panel 557.200.952 / FC718D - Two HP or four SP loop, expandable to eight loop, FireClass Panel

Remote management via Ethernet. Monitors up to 32 FC500 Series panels (FC501, FC503, FC506). Pop-up and audio notification on new events. Traffic light style indicators for panels status. Overall system status indicator. Integrated with FireClass Console and FireClass 500 Console software. Quick link to the FireClass graphic maps. Single log file for the whole monitored system. Data encryption by AES128. Item code/ name: 557.202.726 / FC-MAE

508.070.001 / FCG Soft. Licence-1 Panel 508.070.002 / FCG Soft. Licence 2-4 Panel 508.070.003 / FCG Soft. Licence 5-10 Panel 508.070.004 / FCG Soft. Licence 11-24 Panel 508.070.005 / FCG Additional Client licence

The FC460 range of detectors use the FireClass digital protocol to provide robust and reliable communications to the control panel. A wide range of cable types can be used and the open topology capability of the system makes it ideal for the upgrade of older systems whilst reusing the cables to reduce cost. FireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The range includes an Optical/Heat Multisensor and Optical/Heat/CO Triple Multisensor.Automatic self testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector provides instant line of sight. Fourteen EN54 approved modes/sensitivities for the Optical/ Heat Multisensor help to provide one of the best and most versatile detectors on the market.

With its ability to detect a wide range of fires, from flaming to smouldering types, the combined optical and heat multisensor detector is the preferred choice for a range of applications including light industrial, retail and office environments. It operates in a number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions.

For life protection and when the environmental conditions are challenging, the multisensor smoke, heat and CO detector provides the ultimate in detector performance. It uses the three sensor elements in concert to accurately determine the presence of fire with false alarm rejection properties that make it the ideal choice for hotel bedrooms where steam from bathrooms is a common source of false alarms.

More benign environments where any potential fire will be slow burning can be protected using the optical detector. A choice of sensitivities gives this detector a broad range of applications.

The FC400CH is designed to transmit digital signals representing the status of the carbon monoxide and heat elements of the detector. For use with the FireClass 500 panel.

Complimenting the range is the heat sensor which can operate in fixed temperature and rate-of-rise modes. It is most often used in areas where high levels of dust are present or where the environment precludes the use of smoke detectors.
What project teams usually ask about Fireclass.
Speak directly with one of our fire safety engineers.
Call +91 88795 33000Tell us about your building and an engineer will size the panel, select the detectors and quote supply and installation.