Partner of the Year 2024 — Simplex Fire DetectionISO 9001 · 14001 · 45001 Certified
HYGOOD

HYGOOD Clean Agent Suppression

Engineered clean agent suppression for equipment rooms — sized to the volume and proven to hold concentration.

Explore Products
HYGOOD
Brand overview

Clean Agent Suppression by HYGOOD

HYGOOD's clean agent systems protect enclosures where water-based suppression would do more damage than the fire. The agent reaches design concentration within seconds and leaves no residue to clean up afterwards.

The engineering that matters is in the sizing and the enclosure: the agent has to reach concentration throughout the volume and hold it long enough for the fire to be properly out. Intech designs, installs, commissions and maintains these systems.

  • No residue Nothing to clean up beyond ventilating the room.
  • Calculated to the room Agent quantity follows the volume and the design concentration.
  • Hold time proven Room integrity testing at commissioning rather than assumed.
  • Interlocked Detection, dampers, air handling and door release as one sequence.
System

How Clean Agent Suppression Works

01

Detect

Two independent detectors must confirm before anything is released.

02

Warn and hold

Occupants are alerted, with a discharge delay and a manual lock-off.

03

Discharge

The agent floods the enclosure and reaches design concentration in seconds.

04

Hold concentration

A sealed room keeps the agent long enough for the fire to be properly out.

Our services

HYGOOD Supply, Installation and Support

Product selection and consultation

Choosing the right model for the application rather than the catalogue.

System design and engineering

Layout, sizing and the cause-and-effect where the system drives something.

Installation and commissioning

Installed, commissioned and proven as one tested sequence.

Upgrades and expansion

Extending or replacing an existing installation without starting again.

Preventive maintenance and AMC

Scheduled inspection and testing with a documented record.

Troubleshooting and support

Fault diagnosis from the team that commissioned the system.

Resources

HYGOOD Datasheets

Every datasheet we hold for the range, linked directly. 1 documents.

Full range

The Complete HYGOOD Range We Supply

Models & variants

FM200 BASED 25 BAR GAS SUPPRESSION SYSTEM

FM200 BASED 25 BAR GAS SUPPRESSION SYSTEM

Those responsible for managing and protecting high-value assets, processes, and facilities demand the quality fire suppression offered by the ANSUL® FM-200™ Clean Agent Fire Suppression System. FM-200 systems are internationally accepted as providing reliable, effective, affordable fire protection solutions for applications found in telecommunication sites, data centers and archives, museums, oil and gas facilities, power plants, and more. The ANSUL FM-200 Clean Agent Fire Suppression System is approved by Factory Mutual (FM) and listed by Underwriters Laboratories (UL) for Class A, B and C fires. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection.​​​​ 1101, 11th floor Technocity IT Premises co-op Society, Sector X-5/3, TTC Industrial Area, Mahape Navi Mumbai 400710 All Rights Reserved By In

Technical datasheet
FAQ

Frequently Asked Questions

What project teams usually ask about HYGOOD.

Still have a question?

Speak directly with one of our fire safety engineers.

Call +91 88795 33000
What is HYGOOD clean agent?
A clean agent extinguishing system. It suppresses fire without leaving residue, so the protected equipment comes through a discharge intact.
Is it safe for people in the room?
Systems are designed so the concentration suppresses fire while remaining survivable, with a discharge delay, clear warning and a manual lock-off.
Why does the room need sealing?
The agent must hold its concentration long enough for the fire to be out. An unsealed cable entry or oversized door gap leaks it away regardless of how much is installed.
What is a room integrity test?
A measured test at commissioning that establishes how long the enclosure holds the agent. It is how you know the system will work.
What happens after a discharge?
The room is ventilated and cylinders refilled. There is no residue to clean, so recovery is hours rather than weeks.
Does Intech design and maintain it?
Yes — volume calculation, room integrity testing, installation, commissioning and AMC including cylinder weighing.
Genuine product, direct OEM support

Protect Equipment Rooms with Clean Agent Suppression

Tell us about the enclosure and an engineer will calculate the agent quantity and quote the installation.

+91 88795 33000
Chat with an expert
CallWhatsApp