
MX4000 Multi-Loop Control Panel
MZX panels are intelligent LPCB EN54 approved panels, which can be networked and installed to BS5839:Pt.1. The MX4000 supports two MZX DIGITAL…
>
Skip to contentMZX addressable panels, Gen-6 detectors, call points and sounders — a complete detection platform supplied and commissioned by Intech.

Zettler's MZX platform covers addressable control panels, the Gen-6 detector series, indoor, outdoor and intrinsically safe call points, and addressable sounders and visual alarm devices — all on one loop.
Because the devices and panel come from one platform, the loop carries detection, notification and interface devices together rather than needing separate circuits. Intech supplies, installs and maintains the range.
Which panel and device mix suits your building comes out of the site assessment.

MZX panels are intelligent LPCB EN54 approved panels, which can be networked and installed to BS5839:Pt.1. The MX4000 supports two MZX DIGITAL…

With the ability to detect a wide range of fires from flaming to smouldering types, the combined optical and heat multi-sensor detector is the…

More benign environments where any potential fire will be slow burning can be protected using the optical detector. A choice of sensitivities and…
Gen-6 photo, heat and combined detectors report their own address.
Indoor, outdoor and intrinsically safe call points on the same loop.
The MZX panel applies the cause-and-effect for the building.
Addressable sounders and visual alarm devices operate to the strategy.
The MZX platform suits buildings needing detection, notification and interface devices on a single addressable loop.
Mixed areas including classified zones needing IS call points.
Industry detailMulti-tenant buildings with phased evacuation.
Industry detailIntrinsically safe devices for hazardous areas.
Industry detailLarge floor areas with outdoor call points.
Industry detailGuest floors and back-of-house with differing needs.
Industry detailOccupancies with statutory detection requirements.
Industry detailChoosing the right model for the application rather than the catalogue.
Layout, sizing and the cause-and-effect where the system drives something.
Installed, commissioned and proven as one tested sequence.
Extending or replacing an existing installation without starting again.
Scheduled inspection and testing with a documented record.
Fault diagnosis from the team that commissioned the system.
Every datasheet we hold for the range, linked directly. 9 documents.

MZX panels are intelligent LPCB EN54 approved panels, which can be networked and installed to BS5839:Pt.1. The MX4000 supports two MZX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. The panel is constructed with a strong steel enclosure incorporating a removable chassis plate.
Technical datasheet
With the ability to detect a wide range of fires from flaming to smouldering types, the combined optical and heat multi-sensor detector is the preferred choice for a range of applications including light industrial, retail and office environments. It operates in a number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions.
Technical datasheet
More benign environments where any potential fire will be slow burning can be protected using the optical detector. A choice of sensitivities and modes gives this detector a broad range of applications.
Technical datasheet
To compliment the range the heat sensor can operate in fixed temperature and rate-of-rise modes with a number of approved sensitivities. Most often used in areas where high levels of dust are present or where the environment precludes the use of smoke detectors.
Technical datasheet
The CP820 is an indoor MZX addressable manual callpoint with programmable status LED. The CP820 is designed for LPCB approvals. The CP820 provides high speed communication to the MZX panel of a manual fire alarm. The MCP820 offers the same features plus an integrated line isolator. In the event of a short-circuit on the loop, the line isolator isolates the affected part of the loop and ensures that the parts of the loop that are not affected by the failure continue to work.
Technical datasheet
CP830Exn / CP840Ex Break Glass Call Point The CP830Exn and CP840Ex Weatherproof Break Glass Call Points are designed to monitor and signal the condition of a switch contact associated with the break glass. BG MIM800 Callpoint EX II 2 GD An Ex II 2 GD Dust Approved & Increased Safety (EExemd) Resettable Manual Alarm Call Point for use with the EExd Flameproof MIM800 input module in EExd housing on an Addressable Detection & Releasing System in gas and dust explosive risks.
Technical datasheet
The CP830 is an outdoor MZX addressable manual callpoint with programmable status LED. The CP830 is designed for LPCB approvals The CP830 provides high speed communication to the MZX panel of a manual fire alarm. The MCP830 offers the same features plus an integrated line isolator. In the event of a short-circuit on the loop, the line isolator isolates the affected part of the loop and ensures that the parts of the loop that are not affected by the failure continue to work.
Technical datasheet
The P80AV range of compact addressable wall sounders with a Visual Alarm Device (VAD) includes three models with the same low current and high output specification; red and white body indoor models plus an IP rated version for either outdoor or harsh environment applications.
Technical datasheet
The LP Symphoni range of Sounders and Sounder Beacons are designed to operate on the robust MZX digital loop, An internal line isolator automatically provides short circuit protection against cable faults thus reducing the need for additional line isolator modules. The addressable loop powered sounders meet the requirements of EN54 part 3 whilst the loop powered addressable sounders with beacon are also approved to EN54 part 23 as open category devices. A high (103dB) output or low (90dB ) output can be selected for any of the 16 selectable tones.The high brightness LED beacon provides a 2 candela output with adjustable flash rate. Programming has been simplified by allowing the tone, volume and flash rate to be set by the MZX Consys configuration utility. This means adjustments to the settings can be achieved without having to access the sounder location. Changes can be made to all soun
Technical datasheetWhat project teams usually ask about Zettler.
Speak directly with one of our fire safety engineers.
Call +91 88795 33000Tell us about your building and an engineer will size the panel, select the devices and quote supply and installation.