Partner of the Year 2024 — Simplex Fire DetectionISO 9001 · 14001 · 45001 Certified
Zettler

Zettler Fire Detection Systems

MZX addressable panels, Gen-6 detectors, call points and sounders — a complete detection platform supplied and commissioned by Intech.

Explore Products
Zettler
Brand overview

Fire Detection by Zettler

Zettler's MZX platform covers addressable control panels, the Gen-6 detector series, indoor, outdoor and intrinsically safe call points, and addressable sounders and visual alarm devices — all on one loop.

Because the devices and panel come from one platform, the loop carries detection, notification and interface devices together rather than needing separate circuits. Intech supplies, installs and maintains the range.

  • One addressable loop Detectors, call points and sounders share the same circuit.
  • Gen-6 detector series Photo, heat and combined photo-heat devices selected per area.
  • Indoor, outdoor and IS call points Including intrinsically safe devices for classified areas.
  • Addressable notification Wall sounders and loop-powered sounder-beacons on the same loop.
System

How an MZX System Is Put Together

01

Detection

Gen-6 photo, heat and combined detectors report their own address.

02

Manual initiation

Indoor, outdoor and intrinsically safe call points on the same loop.

03

Control

The MZX panel applies the cause-and-effect for the building.

04

Notification

Addressable sounders and visual alarm devices operate to the strategy.

Our services

Zettler Supply, Installation and Support

Product selection and consultation

Choosing the right model for the application rather than the catalogue.

System design and engineering

Layout, sizing and the cause-and-effect where the system drives something.

Installation and commissioning

Installed, commissioned and proven as one tested sequence.

Upgrades and expansion

Extending or replacing an existing installation without starting again.

Preventive maintenance and AMC

Scheduled inspection and testing with a documented record.

Troubleshooting and support

Fault diagnosis from the team that commissioned the system.

Full range

The Complete Zettler Range We Supply

Models & variants

MX4000 Multi-Loop Control Panel

MX4000 Multi-Loop Control Panel

MZX panels are intelligent LPCB EN54 approved panels, which can be networked and installed to BS5839:Pt.1. The MX4000 supports two MZX DIGITAL detection loops and can be expanded to four loops supporting up to 1000 addressable devices. The panel is constructed with a strong steel enclosure incorporating a removable chassis plate.

Technical datasheet
850PH and 830PH Gen-6 Photo Heat Detectors

850PH and 830PH Gen-6 Photo Heat Detectors

With the ability to detect a wide range of fires from flaming to smouldering types, the combined optical and heat multi-sensor detector is the preferred choice for a range of applications including light industrial, retail and office environments. It operates in a number of approved modes and sensitivities that can be dynamically selected to suit different environmental conditions.

Technical datasheet
850P and 830P Gen-6 Photo Detectors

850P and 830P Gen-6 Photo Detectors

More benign environments where any potential fire will be slow burning can be protected using the optical detector. A choice of sensitivities and modes gives this detector a broad range of applications.

Technical datasheet
850H and 830H Gen-6 Heat Detectors

850H and 830H Gen-6 Heat Detectors

To compliment the range the heat sensor can operate in fixed temperature and rate-of-rise modes with a number of approved sensitivities. Most often used in areas where high levels of dust are present or where the environment precludes the use of smoke detectors.

Technical datasheet
MZX Indoor Callpoints

MZX Indoor Callpoints

The CP820 is an indoor MZX addressable manual callpoint with programmable status LED. The CP820 is designed for LPCB approvals. The CP820 provides high speed communication to the MZX panel of a manual fire alarm. The MCP820 offers the same features plus an integrated line isolator. In the event of a short-circuit on the loop, the line isolator isolates the affected part of the loop and ensures that the parts of the loop that are not affected by the failure continue to work.

Technical datasheet
MZX Intrinsically Safe Addressable Callpoints

MZX Intrinsically Safe Addressable Callpoints

CP830Exn / CP840Ex Break Glass Call Point The CP830Exn and CP840Ex Weatherproof Break Glass Call Points are designed to monitor and signal the condition of a switch contact associated with the break glass. BG MIM800 Callpoint EX II 2 GD An Ex II 2 GD Dust Approved & Increased Safety (EExemd) Resettable Manual Alarm Call Point for use with the EExd Flameproof MIM800 input module in EExd housing on an Addressable Detection & Releasing System in gas and dust explosive risks.

Technical datasheet
MZX Outdoor Callpoints

MZX Outdoor Callpoints

The CP830 is an outdoor MZX addressable manual callpoint with programmable status LED. The CP830 is designed for LPCB approvals The CP830 provides high speed communication to the MZX panel of a manual fire alarm. The MCP830 offers the same features plus an integrated line isolator. In the event of a short-circuit on the loop, the line isolator isolates the affected part of the loop and ensures that the parts of the loop that are not affected by the failure continue to work.

Technical datasheet
Addressable Wall Sounder VADs

Addressable Wall Sounder VADs

The P80AV range of compact addressable wall sounders with a Visual Alarm Device (VAD) includes three models with the same low current and high output specification; red and white body indoor models plus an IP rated version for either outdoor or harsh environment applications.

Technical datasheet
Symphoni Loop Powered Sounders

Symphoni Loop Powered Sounders

The LP Symphoni range of Sounders and Sounder Beacons are designed to operate on the robust MZX digital loop, An internal line isolator automatically provides short circuit protection against cable faults thus reducing the need for additional line isolator modules. The addressable loop powered sounders meet the requirements of EN54 part 3 whilst the loop powered addressable sounders with beacon are also approved to EN54 part 23 as open category devices. A high (103dB) output or low (90dB ) output can be selected for any of the 16 selectable tones.The high brightness LED beacon provides a 2 candela output with adjustable flash rate. Programming has been simplified by allowing the tone, volume and flash rate to be set by the MZX Consys configuration utility. This means adjustments to the settings can be achieved without having to access the sounder location. Changes can be made to all soun

Technical datasheet
FAQ

Frequently Asked Questions

What project teams usually ask about Zettler.

Still have a question?

Speak directly with one of our fire safety engineers.

Call +91 88795 33000
What is MZX?
Zettler's addressable platform. Detectors, call points, sounders and interface devices share one loop back to the control panel.
What are Gen-6 detectors?
Zettler's addressable detector series, available as photo, heat and combined photo-heat devices so the type can be matched to each area.
Do you supply intrinsically safe call points?
Yes — the range includes intrinsically safe addressable call points for classified areas, alongside indoor and outdoor types.
Can sounders run on the same loop?
Yes. Addressable wall sounders and loop-powered sounder-beacons sit on the detection loop rather than needing separate circuits.
Can an existing MZX panel be extended?
Often yes, depending on spare loop capacity, which we confirm against the installed equipment.
Does Intech install and maintain it?
Yes — selection, design, installation, commissioning and AMC with a documented service record.
Genuine product, direct OEM support

Find the Right Zettler System for Your Building

Tell us about your building and an engineer will size the panel, select the devices and quote supply and installation.

+91 88795 33000
Chat with an expert
CallWhatsApp