PROH20 WATER LEAK DETECTION CABLE
When water comes into contact with the detection cable a control unit can detect changes in the electrical characteristics of the cable and signal an…
>
Skip to contentSensing cable that reports where water is escaping, not just that it is — for raised floors, plant rooms and critical pipework.

ProH2O is Thermocable's water leak detection range. Sensing cable is laid along the pipework and the low line of the floor void, so the detection follows the same path the water will rather than waiting at a convenient point.
Locating versions measure along the cable and report the approximate distance to the leak, which on a long run under a raised floor turns an alarm into an instruction. Intech surveys the route, installs and maintains the range.
Whether a locating or a simple zone system suits depends on the length of run and the cost of searching it.

When water comes into contact with the detection cable a control unit can detect changes in the electrical characteristics of the cable and signal an…

The ProH2O Professional module is a water leak detection system for use in conjunction with ProH2O Water Leak Detection cable. It incorporates…
Sensing cable is routed along pipework and the low points of the void.
The panel monitors the cable's electrical characteristics along its length.
Water bridging the cable changes those characteristics and the distance is calculated.
Local and remote alarms are raised, and valve isolation driven where fitted.
The system costs a fraction of one flooded UPS room, which is why it usually pays for itself the first time it catches something.
Raised floors, CRAC units and chilled water pipework.
Industry detailWhere water reaching energised equipment causes an outage.
Industry detailProcess and purified water distribution.
Industry detailIrreplaceable records below pipework or plant.
Industry detailRiser and plant room pipework above occupied space.
Industry detailLow points where ingress collects unnoticed.
Industry detailChoosing the right model for the application rather than the catalogue.
Layout, sizing and the cause-and-effect where the system drives something.
Installed, commissioned and proven as one tested sequence.
Extending or replacing an existing installation without starting again.
Scheduled inspection and testing with a documented record.
Fault diagnosis from the team that commissioned the system.
Every datasheet we hold for the range, linked directly. 2 documents.

When water comes into contact with the detection cable a control unit can detect changes in the electrical characteristics of the cable and signal an alarm or other action. The sensor cable is available in pre-terminated lengths for simple assembly and extension. Non-sensing pre-terminated lengths are also available when the cable is to pass through areas which do not require protection.
Technical datasheet
The ProH2O Professional module is a water leak detection system for use in conjunction with ProH2O Water Leak Detection cable. It incorporates integrated alarm location which will automatically determine the distance along the length of cable to the water leak. The module is designed for simple and straightforward installation and operation. The ProH2O Professional module may be used as a standalone system or integrated with an addressable/ conventional fire alarm or building management system. In each case the ProH2O Professional module will continuously monitor from 30m (100ft) to 305m (1000ft) of ProH2O Water Leak Detection Cable for a water leak or fault condition (such as a break in the detection cable).
Technical datasheet
The ProH2O Module unit is compatible with any addressable zone monitor and fire alarm control panel to enhance a conventional system with water leak detection. The unit houses a low-power circuit which continuously monitors the attached detection cable for leaks and faults along its entire length. The presence of water between the two conductive cores triggers the alarm relay and subsequently the addressable module or fire alarm control panel. A break in the detection cores or power loss to the module will trigger the fault circuit triggering a trouble signal on the addressable module or fire alarm control panel. 1101, 11th floor Technocity IT Premises co-op Society, Sector X-5/3, TTC Industrial Area, Mahape Navi Mumbai 400710 All Rights Reserved By Intech Fire & Security Pvt Ltd.
What project teams usually ask about Thermocable ProH2O.
Speak directly with one of our fire safety engineers.
Call +91 88795 33000Tell us about your pipework and floor void and an engineer will specify the cable run and quote installation.