Skip to contentDedicated extinguishant release control — supervised actuator circuits, abort and manual release, commissioned with the suppression system it drives.

A gas release panel is not a general fire alarm panel. It supervises the detection that confirms a fire, applies the double-knock logic that prevents a single device causing a discharge, runs the discharge delay and drives the actuator circuit.
Kentec's GRP range covers single and multi-area release control with the status indication, abort and manual release facilities a supervised releasing system requires. Intech supplies these as part of the suppression system they control, and commissions the whole sequence as one test.
Which panel suits depends on the number of protected areas and what the discharge has to interlock with.

The Sigma A-Si range of status indicators provides detailed status information for Sigma A-XT releasing control equipment. All models provide high…

The Sigma A-XT Ancillary Board is compatible with all Sigma A-XT control panels. The board provides volt-free, normally-open contacts, enabling…

Key removable in either position Both sides of solenoid circuit are mechanically disabled during activation Disablement illuminated at panel when…
Two independent detectors in the protected area must confirm.
Occupants are alerted and a discharge delay runs, with manual hold available.
The panel drives the supervised actuator circuit to discharge the agent.
Dampers, air handling and door release operate as part of the same sequence.
Wherever a gaseous or clean agent suppression system protects an enclosure, a release panel controls it.
Clean agent protection for equipment rooms.
Industry detailElectrical rooms where water would spread the damage.
Industry detailIrreplaceable contents under gaseous protection.
Industry detailProcess control rooms that stop production when lost.
Industry detailWhere contamination matters as much as the fire.
Industry detailHigh-value, low-occupancy protected rooms.
Industry detailChoosing the right model for the application rather than the catalogue.
Layout, sizing and the cause-and-effect where the system drives something.
Installed, commissioned and proven as one tested sequence.
Extending or replacing an existing installation without starting again.
Scheduled inspection and testing with a documented record.
Fault diagnosis from the team that commissioned the system.
Every datasheet we hold for the range, linked directly. 2 documents.

The Sigma A-Si range of status indicators provides detailed status information for Sigma A-XT releasing control equipment. All models provide high brightness, LED indication of Manual Only, Automatic and Manual, Abort Operated, Disabled, Imminent and Released conditions. Models are also available with zonal fire indicators and a common trouble indicator. For systems where local control of the Automatic/ Manual mode and or a Manual extinguishant release control are required, units are available with these controls fitted. All models have supervised inputs for the remote connection of Automatic/Manual mode and abort switches.
Technical datasheet
Key removable in either position Both sides of solenoid circuit are mechanically disabled during activation Disablement illuminated at panel when active

The Sigma A-XT Abort Switch connects to the Abort terminals of the Sigma A-XT releasing panel. Any number of Sigma A-Si Abort Switches may be connected to the circuit. The last switch must have the end-of-line device from the Abort circuit terminals of the Sigma A-XT releasing panel fitted across its connections to provide open and short circuit supervision. The unit is supplied mounted to a steel enclosure but may also be flush mounted to a single gang electrical box.

The Sigma A-XT Ancillary Board is compatible with all Sigma A-XT control panels. The board provides volt-free, normally-open contacts, enabling control of sub-systems and plant remotely from the main panel over a two-wire data bus. Ancillary boards require only a two-core data cable from the main control panel and a two-core power cable from the main panel. Up to seven Ancillary boards can be connected to a control panel and each is allocated an address from one to seven using a binary coded DIL switch. A mixture of status units and Ancillary boards, up to a maximum of seven of each type, can be connected to the serial data bus. 1101, 11th floor Technocity IT Premises co-op Society, Sector X-5/3, TTC Industrial Area, Mahape Navi Mumbai 400710 All Rights Reserved By Intech Fire & Security Pvt Ltd.
Technical datasheetWhat project teams usually ask about Kentec GRP Gas Release Panel.
Speak directly with one of our fire safety engineers.
Call +91 88795 33000Tell us about the enclosure and the agent and an engineer will specify the release panel and commission the sequence.