Partner of the Year 2024 — Simplex Fire DetectionISO 9001 · 14001 · 45001 Certified
INERGEN

INERGEN Inert Gas Suppression

Inert gas suppression that lowers oxygen below what fire needs while remaining survivable for anyone still in the room.

Explore Products
INERGEN
Brand overview

Inert Gas Suppression by INERGEN

INERGEN is an inert gas suppression agent. Rather than chemically interrupting combustion, it reduces the oxygen concentration in the enclosure to a level that will not sustain a fire but remains breathable, which is why it is specified for rooms that may be occupied.

Because the agent is composed of gases already present in air, there is nothing to clean up and no residue to damage equipment. Intech calculates the agent quantity, tests the enclosure, installs and maintains the system.

  • Breathable at design concentration Oxygen is reduced below what fire needs while remaining survivable.
  • No residue at all The agent is composed of gases already present in air.
  • Sized to the volume Quantity follows the volume calculation and the design concentration.
  • Hold time proven Room integrity testing at commissioning rather than assumed.
System

How Inert Gas Suppression Works

01

Detect

Two independent detectors must confirm before anything is released.

02

Warn and hold

Occupants are alerted, with a discharge delay and a manual lock-off.

03

Discharge

The agent floods the enclosure and reaches design concentration in seconds.

04

Hold concentration

A sealed room keeps the agent long enough for the fire to be properly out.

Our services

INERGEN Supply, Installation and Support

Product selection and consultation

Choosing the right model for the application rather than the catalogue.

System design and engineering

Layout, sizing and the cause-and-effect where the system drives something.

Installation and commissioning

Installed, commissioned and proven as one tested sequence.

Upgrades and expansion

Extending or replacing an existing installation without starting again.

Preventive maintenance and AMC

Scheduled inspection and testing with a documented record.

Troubleshooting and support

Fault diagnosis from the team that commissioned the system.

Full range

The Complete INERGEN Range We Supply

Models & variants

INERGEN BASED 200/150 BAR GAS SUPPRESSION SYSTEM

INERGEN BASED 200/150 BAR GAS SUPPRESSION SYSTEM

The INERGEN Fire Suppression System protects enclosed areas where people may be present, fire may strike day or night, and damage from conventional agents cannot be tolerated. Upon discharge, INERGEN agent fills the room, mixing with the air to suppress fires quickly and effectively. Safe for people, INERGEN agent is non-synthetic and made of naturally occurring gases: nitrogen, argon, and carbon dioxide. Once discharged, it returns to the atmosphere in its natural state. INERGEN agent is free of residues and corrosive by-products that may produce further property damage. And because it poses no ozone depleting or global warming threat,INERGEN agent will never be subject to future legislative bans

Technical datasheet
INERGEN BASED 300 Bar Gas Suppression System with IFLOW Technology

INERGEN BASED 300 Bar Gas Suppression System with IFLOW Technology

Using innovative iFLOW delivery technology, the INERGEN® 300-Bar Clean-Agent Fire Suppression System provides a regulated agent discharge into the protected hazard area. INERGEN agent is composed of naturally-occurring gases found in the air we breathe. Unlike other inert gas agents, INERGEN agent includes a small percentage of carbon dioxide which enhances its ability to sustain life in a reduced oxygen atmosphere. INERGEN agent is nontoxic, does not produce corrosive decomposition products when exposed to fire and is designed to protect valuable or sensitive assets that could be damaged by conventional agents. When discharged, it will not produce a fog, so escape routes will remain visible. And in the aftermath of an incident, the agent simply returns to the atmosphere in its natural state causing no environmental impact. 1101, 11th floor Technocity IT Premises co-op Society, Sector X-

Technical datasheet
FAQ

Frequently Asked Questions

What project teams usually ask about INERGEN.

Still have a question?

Speak directly with one of our fire safety engineers.

Call +91 88795 33000
What is INERGEN?
A clean agent extinguishing system. It suppresses fire without leaving residue, so the protected equipment comes through a discharge intact.
Is it safe for people in the room?
Systems are designed so the concentration suppresses fire while remaining survivable, with a discharge delay, clear warning and a manual lock-off.
Why does the room need sealing?
The agent must hold its concentration long enough for the fire to be out. An unsealed cable entry or oversized door gap leaks it away regardless of how much is installed.
What is a room integrity test?
A measured test at commissioning that establishes how long the enclosure holds the agent. It is how you know the system will work.
What happens after a discharge?
The room is ventilated and cylinders refilled. There is no residue to clean, so recovery is hours rather than weeks.
Does Intech design and maintain it?
Yes — volume calculation, room integrity testing, installation, commissioning and AMC including cylinder weighing.
Genuine product, direct OEM support

Protect Occupied Critical Rooms with Inert Gas

Tell us about the room and its occupancy and an engineer will size the system and quote installation.

+91 88795 33000
Chat with an expert
CallWhatsApp