4100ES Fire Alarm Control Unit
Addressable control unit for large, networked installations across multiple buildings.
>
Skip to contentIntelligent fire detection and alarm solutions for modern buildings — addressable control panels, releasing systems and emergency communication, supplied and commissioned by Intech.

Simplex is a fire alarm and emergency communication brand within Johnson Controls. The ES range of addressable control units covers everything from a single compact panel to a networked installation across a campus, with the same device-level addressing and the same programming environment throughout.
That consistency is the practical reason buildings standardise on it. A site that grows, or that adds a building, extends the system it already has rather than running a second one alongside. Intech supplies, installs and maintains the range as an authorised partner.
These are the Simplex categories Intech actually stocks and installs. Each one links to the full model list further down the page.

Addressable control units across the ES range, from compact single-panel installations to large networked sites.

Releasing control for gas and clean agent systems, with actuator supervision and release circuits.

Manual release, abort and maintenance disconnect devices for supervised releasing systems.

Loop devices that extend notification circuits and carry IDNet communications across the system.

Two-way emergency communication for areas of refuge and assisted evacuation.
Three addressable control units from the ES range, each with its datasheet. Which one suits your building comes out of the site assessment.

Addressable control unit for large, networked installations across multiple buildings.

Addressable control unit for mid-size buildings and campus installations.

Compact addressable control unit for smaller buildings and single-panel sites.
Addressable detectors and manual call points report their own identity to the panel.
The control unit resolves each address to a location and applies the cause-and-effect.
Sounders and visual alarm devices operate to the evacuation strategy for the building.
Releasing, lift recall, dampers and door release are driven where the design calls for it.
Detection requirements differ considerably by building type. The panel platform may be the same; the devices on it and the evacuation strategy are not.
Phased evacuation and dependency on continuity of care.
Industry detailMulti-tenant floors with phased evacuation and lift recall.
Industry detailLarge public volumes with voice notification requirements.
Industry detailMultiple buildings networked back to one monitored system.
Industry detailGuest floors, kitchens and back-of-house with differing detection needs.
Industry detailMixed environments needing different detector types per area.
Industry detailChoosing the right platform and devices for the building rather than the catalogue.
Device layout, loop design and the cause-and-effect matrix.
Installed, commissioned and proven as one tested sequence.
Extending or replacing an existing Simplex installation without starting again.
Scheduled inspection and testing with a device-by-device record.
Fault diagnosis and technical support from the team that commissioned it.
Every datasheet we hold for the range, linked directly. 14 documents.

4004R is a two-hazard releasing system that incorporates big-panel features into a small and cost-effective package. Its dual hazards can be programmed to provide an agent release for one hazard and preaction or deluge for the other, giving a high degree of flexibility and protection. With the early detection capability of the agent release hazard, the fire should be extinguished before the preaction or deluge system is activated.
Technical datasheet
Releasing systems require maintenance disconnect switches and often require abort switches. These abort and maintenance switches are clearly labeled and combine easy operation with rugged construction for high integrity operation.
Technical datasheet
Releasing systems often require abort switches. These abort switches are clearly labeled, have a visually striking blue plate and combine easy operation with rugged construction for high integrity operation.
Technical datasheet

When combined with Suppression Release Peripherals, the 4007ES series fire alarm control panel provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4007ES capabilities. The necessary releasing system logic is implemented within the 4007ES control panel as required for the local application.
Technical datasheet
When combined with Suppression Release Peripherals, the 4010ES series fire alarm control unit provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4010ES capabilities. The necessary releasing system logic is implemented within the 4010ES control unit as required for the local application
Technical datasheet
When combined with Suppression Release Peripherals, the 4100ES series fire alarm control panel provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4100ES capabilities. The necessary releasing system logic is implemented within the 4100ES control panel as required for the local application.
Technical datasheet
For facilities requiring from five to ten initiating zones, the Simplex 4006 Series conventional fire alarm control panels provide flexible initiating circuit monitoring, extensive programmable control capability, and central station connectivity.
Technical datasheet
Simplex fire alarm solutions are trusted the world over, helping protect millions of people every day in large facilities that range from hospitals, hotels and universities to airports, office buildings and sky scrapers. Customers choose Simplex products for their industry-leading scalability, reliability, long-term value and technology. Now, the Simplex 4007ES panel brings advanced Simplex performance to smaller facilities.
Technical datasheet
Simplex fire alarm solutions are trusted the world over, helping protect millions of people every day in large facilities that range from hospitals, hotels and universities to airports, office buildings and sky scrapers. Customers choose Simplex products for their industry-leading scalability, reliability, long-term value and technology. Now, the Simplex 4007ES panel brings advanced Simplex performance to smaller facilities.
Technical datasheet
Provides additional notification appliance circuit (NAC) capacity with flexible operation modes and power-limited design Four, Class B NACs are standard: Rated 2 A each for conventional reverse polarity 24 VDC notification appliances and providing multiple operation modes Can be selected to provide synchronization for Simplex® visible notification strobe flashes Capable of controlling TrueAlert non-addressable notification appliances operating with SmartSync two-wire control mode*
Technical datasheet
The Simplex 4010ES fire alarm system is a highly flexible and powerful 1,000-point addressable analog system for small- to mid-sized facilities. Unlike many systems of this size, points can be used for detectors, modules or manual stations as needed to meet the requirements of each building. Labor-saving features such as device-level ground fault isolation and almost dirty smoke sensor status reports reduce installation time for electrical contractors and allows for proactive maintenance to be scheduled at one-time to help eliminate unwanted nuisance alarms for owners and end-users.
Technical datasheet
4100ES addressable fire alarm control panels support up to 2,500 points, fire alarm and emergency voice communication, self-testing notification appliances and IP based networking. With scalable architecture and future-proof design, 4100ES panels are ideal for medium to large facilities and multi-building campus style networks. All Simplex addressable panels rely on TrueAlarm addressable detectors.
Technical datasheet
An Area of Refuge solution that’s easier to install, more reliable, and more effective. An “Area of Refuge” or “Area of Rescue” is a location that’s designed to keep building occupants safe during a fire or emergency until they can be evacuated. The need for an Area of Refuge is particularly acute when immediate evacuation is impossible or there are occupants with mobility challenges. The Detect360 Area of Refuge Communications System provides a reliable and effective code-compliant Area of Refuge solution that enables occupants to remain safe and stay informed, and provides the information rescuers need to get them quickly evacuated. 1101, 11th floor Technocity IT Premises co-op Society, Sector X-5/3, TTC Industrial Area, Mahape Navi Mumbai 400710 All Rights Reserved By Intech Fire & Security Pvt Ltd.
Technical datasheetWhat project teams usually ask about Simplex systems.
Speak directly with one of our fire safety engineers.
Call +91 88795 33000Tell us about your building and an engineer will help you select an appropriate system, then quote supply, installation and commissioning.